饿虎岗资源网 Design By www.oxmxm.com

机房断电后重启pg数据库,报如下错误:

< 2019-01-01 22:42:59.240 EST >LOG: database system was interrupted while in recovery at 2019-01-01 22:00:58 EST
< 2019-01-01 22:42:59.240 EST >HINT: This probably means that some data is corrupted and you will have to use the last backup for recovery.
< 2019-01-01 22:42:59.241 EST >LOG: database system was not properly shut down; automatic recovery in progress
< 2019-01-01 22:42:59.333 EST >PANIC: unexpected pageaddr 26EA/46000000 in log segment 00000001000026EA00000017, offset 0
< 2019-01-01 22:42:59.333 EST >LOG: startup process (PID 88586) was terminated by signal 6: Aborted
< 2019-01-01 22:42:59.333 EST >LOG: aborting startup due to startup process failure

修复方法:

切换到bin目录下:

cd /usr/pgsql-9.3/bin

使用pg_resetxlog命令修复日志:(/var/lib/pgsql/9.3/data为pg_data的目录)

pg_resetxlog -f /var/lib/pgsql/9.3/data

重启数据库:

pg_ctl start

补充:PostgreSQL 数据库服务无法启动的解决方法

因为客户那边的磁盘一般是FAT32的文件系统,所以我们程序安装时,采用手动安装PostgreSQL的形式安装数据库,但初始化数据库群成功并且成功注册了系统服务后,

发现PostgreSQL的服务总是启动不了,提示服务启动又停止了,然后在系统时间查看器里发现报的错误是:Could not create inherited socket, 错误编码为10022

解决方法:

运行 netsh winsock reset,重启电脑,OK!

以上为个人经验,希望能给大家一个参考,也希望大家多多支持。如有错误或未考虑完全的地方,望不吝赐教。

饿虎岗资源网 Design By www.oxmxm.com
广告合作:本站广告合作请联系QQ:858582 申请时备注:广告合作(否则不回)
免责声明:本站资源来自互联网收集,仅供用于学习和交流,请遵循相关法律法规,本站一切资源不代表本站立场,如有侵权、后门、不妥请联系本站删除!
饿虎岗资源网 Design By www.oxmxm.com

RTX 5090要首发 性能要翻倍!三星展示GDDR7显存

三星在GTC上展示了专为下一代游戏GPU设计的GDDR7内存。

首次推出的GDDR7内存模块密度为16GB,每个模块容量为2GB。其速度预设为32 Gbps(PAM3),但也可以降至28 Gbps,以提高产量和初始阶段的整体性能和成本效益。

据三星表示,GDDR7内存的能效将提高20%,同时工作电压仅为1.1V,低于标准的1.2V。通过采用更新的封装材料和优化的电路设计,使得在高速运行时的发热量降低,GDDR7的热阻比GDDR6降低了70%。

更新日志